   Willamette  Wood Construction Connectors  

Wood Construction Connectors - Page 25

 

 

® ET EPOXY-TIE ADHESIVE AND STRONG-TIE ANCHORS
ANCHORS

 

Request our Anchoring Systems Catalog for complete information.

Epoxy-Tie ET is a two-component, 100% solid epoxy based adhesive for use as a high strength, non-shrink anchor grouting material. Resin and hardener are dispensed and mixed simultaneously through the mixing nozzle. ET meets the ASTM C-881-90 specification for Type I, II, IV and V Grade 3, Class B, and C.

APPLICATION:

  • Surfaces to receive epoxy must be clean dry. Epoxy should not be installed in or through standing water.
  • The base material temperature must be 40° F or above at the time of installation. For best results, material should be 70° F - 80° F at the time of application.
  • Cartridges should not be immersed in water to facilitate warming. To warm cold material, the cartridges should be stored in a warm, uniformly heated area or storage container for a sufficient time to allow epoxy to warm completely.
  • Mixed material in nozzle will harden in 7 -10 minutes at a temperature of 40° F or above.

CODES: ICBO 4945; SBCCI 94145; City of L.A. RR25185, RR25120.


Our comprehensive Mechanical Anchor line offers load-rated connections for different materials:

  • hollow concrete block
  • solid brick
  • concrete
  • grout-filled concrete block
  • hollow brick

Loads for Threaded Rod Anchors in Concrete

Stud Dia Drill Bit Dia Embed Depth Spacing Edge Dist Tension Loads (lbs) Shear Loads (lbs)
Based on Bond Strength Based on Steel Strength Based on Steel Strength
f'c >= 2000 psi A307 (SAE1018) A307 (SAE 1018)
Ultimate Load Allowable Load5 Allowable Load Allowable Load
3/8 1/2 3-1/2 6-1/8 5-1/4 8776 2195 2105 1085
1/2 5/8 4-1/4 7-1/2 6-3/8 15368 3840 3750 1930
5/8 3/4 5 8-3/4 7-1/2 22876 5720 5875 3025
3/4 7/8 6-3/4 12 10-1/8 35460 8865 8460 4360
7/8 1 7-3/4 13-5/8 11-5/8 43596 10900 11500 5925
1 1-1/8 9 15-3/4 13-1/2 47332 11835 15025 7740

 

 

 

 

 

 

 

 

  1. Allowable loads are based on a 4 times factor of safety.
  2. Allowable load is the lesser of the load based on bond strength, connector or steel strength.

Tension Loads for Threaded Rod Anchors in Concrete Foundation Stemwall Installation

Stud Dia Drill Bit Dia Min Embed Min Wall Thickness Min Edge Dist Min End Dist Avg Ult Tension Allowable Tension Load f'c ³ 2000 psi
5/8 3/4 9-1/2, 6 1-3/4 5 10720 2680
5/8 3/4 12 6 1-3/4 5 16160 4040
7/8 1 12-1/2 8 1-3/4 5 17000 4250
7/8 1 15-1/2 8 1-3/4 5 23340 5835

 

 

 

 

 

Model No Min Edge Distance Compatible Products
WA50334 5 FAP, FA6, FA8, HFA6, HFA8, FJA, FSA, ABA44, ABA44R, ABE44, ABE44R, AB series
WA62312 6-1/4 ABU44, ABU46, ABU66,ABE46, ABE46R, ABE66 ABE66R,ABA46, ABA46R,ABA66,ABA66R

 

 

 

  1. Minimum concrete thickness is 4".
  2. Maximum anchor uplift load is 1130 lbs in 2000 psi or 2150 lbs in 4000 psi for all ABU'S.

Request for Information / Request a Catalog from Willamette
 
 
 
To request more information from Willamette, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com