ET EPOXY-TIE ADHESIVE AND
STRONG-TIE ANCHORS
|
Request our Anchoring Systems Catalog
for complete information.
Epoxy-Tie ET is a two-component, 100% solid epoxy based adhesive for
use as a high strength, non-shrink anchor grouting material. Resin and hardener are
dispensed and mixed simultaneously through the mixing nozzle. ET meets the ASTM C-881-90
specification for Type I, II, IV and V Grade 3, Class B, and C.
APPLICATION:
- Surfaces to receive epoxy must be clean dry. Epoxy should not be
installed in or through standing water.
- The base material temperature must be 40° F or above at the time of
installation. For best results, material should be 70° F - 80° F at the time of
application.
- Cartridges should not be immersed in water to facilitate warming. To
warm cold material, the cartridges should be stored in a warm, uniformly heated area or
storage container for a sufficient time to allow epoxy to warm completely.
- Mixed material in nozzle will harden in 7 -10 minutes at a
temperature of 40° F or above.
CODES: ICBO 4945; SBCCI 94145; City of L.A.
RR25185, RR25120.
Our comprehensive Mechanical Anchor line offers load-rated
connections for different materials:
- hollow concrete block
- solid brick
- concrete
- grout-filled concrete block
- hollow brick
Loads for Threaded Rod Anchors in Concrete
| Stud
Dia |
Drill
Bit Dia |
Embed
Depth |
Spacing
|
Edge
Dist |
Tension
Loads (lbs) |
Shear
Loads (lbs) |
| Based
on Bond Strength |
Based
on Steel Strength |
Based
on Steel Strength |
| f'c
>= 2000 psi |
A307
(SAE1018) |
A307
(SAE 1018) |
| Ultimate
Load |
Allowable
Load5 |
Allowable
Load |
Allowable
Load |
| 3/8 |
1/2 |
3-1/2 |
6-1/8 |
5-1/4 |
8776 |
2195 |
2105 |
1085 |
| 1/2 |
5/8 |
4-1/4 |
7-1/2 |
6-3/8 |
15368 |
3840 |
3750 |
1930 |
| 5/8 |
3/4 |
5 |
8-3/4 |
7-1/2 |
22876 |
5720 |
5875 |
3025 |
| 3/4 |
7/8 |
6-3/4 |
12 |
10-1/8 |
35460 |
8865 |
8460 |
4360 |
| 7/8 |
1 |
7-3/4 |
13-5/8 |
11-5/8 |
43596 |
10900 |
11500 |
5925 |
| 1 |
1-1/8 |
9 |
15-3/4 |
13-1/2 |
47332 |
11835 |
15025 |
7740 |
- Allowable loads are based on a 4 times factor of safety.
- Allowable load is the lesser of the load based on bond strength,
connector or steel strength.
Tension Loads for Threaded Rod Anchors in Concrete
Foundation Stemwall Installation
| Stud
Dia |
Drill
Bit Dia |
Min
Embed |
Min
Wall Thickness |
Min
Edge Dist |
Min
End Dist |
Avg
Ult Tension |
Allowable
Tension Load f'c ³ 2000 psi |
| 5/8 |
3/4 |
9-1/2, |
6 |
1-3/4 |
5 |
10720 |
2680 |
| 5/8 |
3/4 |
12 |
6 |
1-3/4 |
5 |
16160 |
4040 |
| 7/8 |
1 |
12-1/2 |
8 |
1-3/4 |
5 |
17000 |
4250 |
| 7/8 |
1 |
15-1/2 |
8 |
1-3/4 |
5 |
23340 |
5835 |
| Model
No |
Min
Edge Distance |
Compatible
Products |
| WA50334 |
5 |
FAP, FA6, FA8, HFA6, HFA8,
FJA, FSA, ABA44, ABA44R, ABE44, ABE44R, AB series |
| WA62312 |
6-1/4 |
ABU44, ABU46, ABU66,ABE46,
ABE46R, ABE66 ABE66R,ABA46, ABA46R,ABA66,ABA66R |
- Minimum concrete thickness is 4".
- Maximum anchor uplift load is 1130 lbs in 2000 psi or 2150 lbs in
4000 psi for all ABU'S.
|