RP6 RETRO PLATE
|

The RP6 heavy steel plate fits on the outside of masonry buildings,
helps tie the walls to the roof or floor structure with a 3/4" diameter bolt.
MATERIAL: 3/8" steel
FINISH: Simpson gray paint. Optional hot-dip
galvanized finish; see Corrosion-Resistance, page 6, and specify
HDG.
INSTALLATION: Use a 3/4" diameter rod.
MKP MONKEY PAW ANCHOR BOLT
HOLDERS
Secure the SSTB to the formboard before the concrete pour. Use the
MKP5/8 to install the SSTB16, 20 and 24; MKP7/8 a for SSTB28, SSTB34 and SSTB36; other
sizes fit commonly-used anchor bolts.
SPECIAL FEATURES:
- The MKP may be used several times.
- Stabilizes bolt by providing three-point support against lateral
concrete pressure.
- Alignment arrows (left or right) match the SSTB bolt head arrow.
- Stamped for 2x4 or 2x6 mudsill placement.
- No nut required to hold bolt in place.
- When removed, the MKP cleans the bolt thread of concrete.
MATERIAL: MKP1/2, MKP5/8 a MKP3/4, -- 16
gauge; all others -- 14 gauge
FINISH: Galvanized
INSTALLATION:
- Attach SSTB to the MKP. Line up MKP arrows with SSTB bolt head arrows
for diagonal installation at approximately 45° from the wall.
- Align bottom tab of MKP with SSTB embedment line.
- Use 2x4 or 2x6 notches to match the mudsill size.
- Attach the MKP to the formboard using duplex nails.
- After concrete pour, allow concrete to cure. Remove the MKP by
squeezing the top and bottom together, lifting and twisting off.
| Model
No. |
Bolt
Dia |
Mudsill
Size |
| MKP1/2 |
1/2 |
2x4 2x6 |
| MKP5/8 |
5/8 |
| MKP3/4 |
3/4 |
| MKP7/8 |
7/8 |
| MKP1 |
1 |
| MKP1-1/8 |
1-1/8 |
| MKP1-1/4 |
1-1/4 |
J/JP FLOOR BEAM LEVELERS

Jack piers and standard floor beam levelers offer unique leveling
simplicity during and after construction. JPs allow two simple methods of installation for
economy and design versatility. Both models are adjustable; see table.
MATERIAL: 12 gauge plates, 3/4" threaded rod,
1-1/16" O.D. steel pipe
FINISH: None. Connectors installed in damp areas,
or corrosive environments that are not exposed to rain or periodic washing, will
deteriorate at a faster rate. Corrosion-resistant finishes and maintenance can improve the
connector's service life.
INSTALLATION:
- Use all specified fasteners. See General Notes.
- Holes are provided for installation with 10dx1-1/2" nails.
- Do not use J/JPs for dynamic jacking of structures, such as houses.
CODES: BOCA, ICBO, SBCCI NER-413. City of LA RR
25119.
| Model
No. |
Dimensions
|
Allowable
Bearing Loads (100) |
| H
(Min-Max) |
Threaded
Rod Length |
| JP44 |
2-4 |
4-3/4 |
44401 |
| J57 |
5-7 |
4 |
4380 |
| J813 |
8-13 |
8 |
4380 |
- Consider allowable loads for 4x4 post.
- Loads may not be increased for short-term loading.
|