BC POST CAPS
|
The BCS allows for the connection of 2-2x's to a 4x post or
3-2x's to a 6x post. Double shear nailing between beam and post gives added strength!
The BC series offers dual purpose post cap/base for light
cap or base connections. MATERIAL: 18 gauge
FINISH: Galvanized
INSTALLATION:
- Use all specified fasteners. See General Notes.
- BCS: install dome nails on beam; drive nails at an angle
through the beam into the post below to achieve the table loads
- BC: install with 16d commons or 16dx2y2" joist hanger
nails.
- Not recommended for non-top-supported installations such as
fences when used as a base.
CODES: BOCA, ICBO, SBCCI NER-421; ICBO
5357; Dade County FL 97-0325.03 City of L.A. RR 25076 (except BCO);
| Model
No. |
Dimensions
|
Fasteners
(Each Side) |
Uplift
Avg Ult |
Allowable
Loads (133 & 160)1 |
| W1 |
W2 |
L1 |
L2 |
H1 |
H2 |
Surface A |
Surface B |
Surface C |
Uplift |
Lateral |
| CAPS |
| BC4 |
3-9/16 |
35-9/16 |
2-7/8 |
2-7/8 |
3 |
3 |
3-16d |
3-16d |
|
3100 |
980 |
1000 |
| BC46 |
3-9/16 |
5-1/2 |
4-7/8 |
2-7/8 |
3/2 |
2/2 |
6-16d |
3-16d |
|
3100 |
980 |
1000 |
| BC4R |
4 |
4 |
4 |
4 |
3 |
3 |
6-16d |
6-16d |
|
3100 |
980 |
1000 |
| BC6 |
5-1/2 |
5-1/2 |
4-3/8 |
2-3/8 |
3-3/8 |
3-3/8 |
6-16d |
6-16d |
|
4700 |
1050 |
2000 |
| BC6R |
6 |
6 |
6 |
6 |
3 |
3 |
6-16d |
6-16d |
|
4700 |
1050 |
2000 |
| BC8 |
7-1/2 |
7-1/2 |
7-1/2 |
7-1/2 |
4 |
4 |
6-16d |
6-16d |
|
5600 |
1800 |
2000 |
| BCS2-2/4 |
3-1/8 |
39-9/16 |
2-7/8 |
2-7/8 |
2-15/16 |
2-15/16 |
4-1 0d |
3-1 0d |
|
2697 |
780 |
1025 |
| BCS2-3/6 |
4-5/8 |
5-9/16 |
4-3/8 |
2-7/8 |
3-5/16 |
2-15/16 |
6-16d |
3-16d |
|
3000 |
800 |
1495 |
| BASES |
| BC40 |
3-9/16 |
|
3-//4 |
|
2-1/4 |
|
3-16d |
|
4-16d |
|
|
535 |
| BC40R |
4 |
|
4 |
|
3 |
|
4-16d |
|
4-16d |
|
|
535 |
| BC460 |
5-1/2 |
|
3-3/8 |
|
3 |
|
4-16d |
|
4-16d |
|
|
535 |
| BC60 |
5-//2 |
|
5-1/2 |
|
3 |
|
6-16d |
|
4-16d |
|
|
535 |
| BC60R |
6 |
|
6 |
|
3 |
|
6-16d |
|
4-16d |
|
|
535 |
1 .Allowable loads have been increased 33% and 60% for
earthquake or wind loading with no further increase allowed; reduce for other load
durations according to the code.
APS ALUMINUM POST STANDOFF

The APS standoff height above concrete or masonry floors or
decks reduces decay at post and column ends.
MATERIAL: Cast aluminum
INSTALLATION:
- See General Notes.
- Attach to post before installation using four nail holes.
- Embed rod into concrete and extend into wood member.
- For nominal or rough sawn lumber.
| Model
No. |
Post
Column Size |
Dimensions
|
Allowable
Down Load2 |
| W |
H |
| APS4 |
4x4 3% |
3 1/4 |
1 |
780 |
| APS5 |
5x5 4% |
4 3/8 |
1 |
1095 |
| APS6 |
6x6 ; 5% |
5 1/8 |
1 |
1095 |
| APS8 |
8x8 8 |
8 |
1 1/4 |
2655 |
| APS10 |
10x10 |
9 3/4 |
1/2 |
3595 |
| APS12 |
12x12 |
113/4 |
1/2 |
4530 |
1. Loads may not be increased for short-term loading.
2. The download is calculated based on the APS bearing area
and concrete strength of 2500 psi. |