   Willamette  Wood Construction Connectors  

Wood Construction Connectors - Page 55

 

 


®

L/LS/GA REINFORCING AND SKEWABLE ANGLES
STRAPS & TIES

The GA Gusset Angles' embossed bend section provides added strength. Staggered nail pattern reduces splitting and allows back-to-back installation.

L--Staggered nail pattern reduces the possibility for splitting and allows installation on both sides of a member. LS--Field-adjustable angles attach members intersecting at angles.

MATERIAL: L--16 gauge; GA and LS--18 gauge

FINISH: Galvanized

INSTALLATION:

  • Use all specified fasteners; see General Notes.
  • LS--field skewable; bend one time only.
  • Joist must be constrained against rotation (for example, with solid blocking) when using a single LS per connection.

CODES: BOCA, ICBO, SBCCI NER-413, NER-443; ICBO 5357; City of L.A. RR 25119 and RR 25149.

Model No. L Fasteners Down Avg Ult Allowable Loads1,2,3
Floor (100) Roof (125)
GA1 2-3/4 4-10d 612 185 185
GA2 3-1/4 6-10d 1600 335 415
L30 3 4-10d 758 220 240
L50 5 6-10d 1983 335 420
L70 7 8-10d 1983 445 555
L90 9 10-10d 4667 555 695
LS30 3-3/8 6-10d 1933 335 395
LS50 4-7/8 8-10d 2180 450 560
LS70 6-3/8 10-10d 4233 560 700
LS90 7-7/8 12-10d 3233 670 840


  1. GA and L angles--loads are for condition F1 or F2; LS angles--loads are for condition F1 only. 
  2. GA1 and GA2 angles--loads for F2 are 220 and 335 lbs (100) and 280 and 415 lbs (125), respectively.
  3. Roof loads are 125% of floor loads unless limited by other criteria; floor loads may be adjusted for other  load durations according to the code, provided they do not exceed those in the roof column.
  4. Loads are for one part only.
  5. Use a minimum lumber thickness of 1-3/4" For 1-1/2" lumber, use 0.81 of table load, except GA1 in F1 direction, use 185 lbs.
  6. Nail the L angle's wider leg into the joist to ensure table loads and allow correct nailing, as shown in the illustration.


STC/STCT/DTC ROOF TRUSS CLIPS


For alignment control between a roof truss and nonbearing walls; the 1-1/2" slot permits vertical truss chord movement when loads are applied.

MATERIAL:18 gauge

FINISH: Galvanized

INSTALLATION:

  • Use all specified fasteners; see General Notes.
  • Use STC or DTC depending on required loads. STC, installed with Drywall Stop (DS), helps prevent fasteners tearing through the ceiling sheetrock (see illustration).
  • Use STCT where truss or rafter is separated from the top plate of the nonbearing wall.
  • Install slot nails in the middle of the slot.
Model No. Dimensions Fasteners Allowable Loads1(133 & 160)
Plate Base Vertical Leg Base Slot Without Gap2 With1/4" Gap3
F1 F2 F1 F2
STC 1-1/4x1-7/8 1-1/4x2-3/4 2-8d 1-8d 85 50 35 35
STCT 1 -1/2x 1-1/4 1-1/4X4-1/4 2-8d 1-8d -- -- -- --
DTC 2-1/2x1-7/8 2-1/2X2-3/4 4-8d 2-8d 125 210 85 135


  1. Loads may not be increased for short-term loading.
  2. Truss or rafter must be bearing on top plate to achieve the allowable loads under "WITHOUT GAP."
  3. Installed with maximum 1/4" space between rafter or truss and top plate under "WITH 1/4 GAP." Where loads are not required, space is not limited to 1/2".

Request for Information / Request a Catalog from Willamette
 
 
 
To request more information from Willamette, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2009 AECinfo.com