DS DRYWALL STOP
|

Eliminates costly blocking at top plate, end walls, and
corners. A typical residence will use several hundred of these inexpensive clips with a
substantial savings in blocking and labor.
The installation prongs provide even more labor savings.
MATERIAL: 20 gauge
FINISH: Galvanized
INSTALLATION: 16" on center or less,
using 8d commons.
CODE: BOCA, ICBO, SBCCI NER-413.
NS NAIL STOPPERS
Help prevent nails from piercing water pipes and electrical
lines. Installed over utilities that pass through framing members, the NS provides a
warning and allows repositioning of the nails.
16 gauge steel conforms to the National Electric Code.
MATERIAL: 16 gauge
FINISH: Galvanized
INSTALLATION: 8d commons or prongs.
HSS/SS STUD SHOES
 |
HSS available Spring 1999 |
|
NEW! HSS Stud Shoes provide tension load capacity as well
as increased compression loads. Flared flange provides greater strength. Installs over
pipe up to 2" diameter.
Stud Shoes reinforce joists, studs, and rafters notched in
construction--NOT a total replacement of removed material.
MATERIAL:18 gauge.
FINISH: Galvanized
INSTALLATION:
Use all specified fasteners. See General Notes.
HSS: Bend flanges at 90° angle during installation,
then bend back and screw into position (screws supplied).
Bend flanges one cycle only.
CODE: BOCA, ICBO, SBCCI NER-432 (SS1,
SS3).
|
|
Model
No. |
W |
Fasteners
|
Avg
Ult |
Allowable
Loads1 |
| Compression
|
Tension
|
| Floor (100) |
Roof (125) |
| SS1 |
1 9/16 |
12-10dx1-1/2 |
1617 |
500 |
500 |
-- |
| SS3 |
3 |
12-10d |
2433 |
665 |
785 |
-- |
 |
HSS2 |
1-9/16 |
12-SDS-1/4x1-1/4 |
3600 |
1200 |
1200 |
1000 |
 |
HSS2-2 |
3 |
12-SDS-1/4x1-1/4 |
3600 |
1200 |
1200 |
1000 |
 |
HSS4 |
3-9/16 |
12-SDS-1/4x1-1/4 |
3600 |
1200 |
1200 |
1000 |
1. Roof loads are 125% of floor loads unless limited by
other criteria. Floor loads may be adjusted for other load durations according to the