   Willamette  StrucJoist SJ-32-42-55  

StrucJoist SJ-32-42-55 - Page 3

 

 

Floor Spans

Joists without web stiffeners

TABLE I Live Load = 40 psf

Dead Load = 12 psf

LL Defl = L/480

    ON - CENTER SPACING
Joist

Series

Joist

Depth

Simple Span Multiple Span
12"o/c 16"o/c 19.2"o/c 24"o/c 12"o/c 16"o/c 19.2"o/c 24"o/c
SJ-32 9-1/2" 18'- 2" 16'- 7" 15'- 7" 14'-1" 19'-11" 17'- 4" 15'- 9" 14'-1"
11-7/8" 21'- 9" 19'- 9" 18'- 3" 16'- 4" 23'- 2" 20'- 0" 18'- 3" 16'-4"
14" 26'-1 " 23'- 9" 22'- 4" 20'- 9" 28'- 7" 25'-11" 23'-10" 19'- 0"
16" 29'- 0" 26'- 4" 24'-10" 22'-11" 31'- 8" 28'- 8" 23'-10" 19'- 0"
SJ-42 9-1/2" 21'-3" 19'- 3" 18'-1" 16'-10" 23'- 2" 21'-0" 19'- 9" 17'-1"
11-7/8" 25'- 4" 23'- 0" 21'-7" 20'- 0" 27'- 8" 25'-1 " 23'- 7" 21'-8"
14" 28'- 9" 26'-1 " 24'- 7" 22'- 9" 31'- 5" 28'- 6" 26'-10" 23'- 0"
16" 31'-11" 28'-11 " 27'- 3" 24'- 6" 34'-10" 31'- 7" 28'-10" 23'- 0"
SJ-55 11-7/8" 26'- 4" 23'-11" 22'- 6" 20'-11" 28'- 9" 26'- 2" 24'- 7" 22'-10"
14" 29'-11" 27'- 2" 25'- 7" 23'- 9" 32'- 9" 29'- 9" 27'-11" 25'- 9"
16" 33'- 2" 30'- 2" 28'- 4" 26'- 4" 36'- 3" 32'-11 " 31'-0" 25'- 9"

Notes:

  1. All spans shown in the tables above are appropriate without web stiffeners at supports. Spans shown in shaded portion of the table can be increased with the addition of web stiffeners at interior supports (See table below).
  2. Spans are based on glued/nailed 3/4" nominal sheathing. Adhesive shall comply with specification AFG-01 of the American Plywood Association. Reduce spans 10" for nailed sheathing only.
  3. Spans are based on clear distance between supports.
  4. Outermost spans in multiple span application must be at least 40% of adjacent span.
WEB STIFFENER ATTACHMENT

 

Web stiffeners:

SJ-32 1" X 2-5/16" net minimum

SJ-42 2 x 3 nominal minimum

SJ-55 2 x 3 nominal minimum

TABLE II

Floor Spans

Joists with Web Stiffeners attached at interior supports

Live Load = 40 psf

Dead Load = 12 psf LL Defl = L/480

Joist

Series

Joist

Depth

ON - CENTER SPACING
Multiple Span
12"o/c 16"o/c 19.2"o/c 24"o/c
SJ-32 9-1/2"        
11-7/8"        
14"     24'-5" 22'-1"
16"   28'-10" 26'-9" 22'-10"
SJ-42 9-1/2"        
11-7/8"        
14"       23'- 8"
16"     29'-7" 23'- 8"
SJ-55 11-7/8"        
14"       25'-11"
16"       26'- 9"

Note:

  1. This table is applicable to joists with web stiffeners at interior supports or joists without web stiffeners when interior supports are a minimum of 5-1/4" wide.
Please see the SJ-32 SJ-42 SJ-55 Installation Guide for additional information.

Request for Information / Request a Catalog from Willamette
 
 
 
To request more information from Willamette, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com