| Search |
|
|
|
| |
| Site Navigation |
|
|
|
| News / Publications |
|
|
|
| Jobs | |
|
|
| Service |
|
|
|
|
|


|
| |
|
| |
Willamette StrucJoist SJ-32-42-55 StrucJoist SJ-32-42-55 - Page 5
TABLE VI
| |
SJ-32
Floor Load Table Allowable Load in
Pounds per Lineal Foot |
SJ-42
Floor Load Table Allowable Load in
Pound per Lineal Foot |
| Span (ft) |
9-1/2" |
11-7/8" |
14" |
16" |
9-1/2" |
11-7/8" |
14" |
16" |
| Live Load |
Total Load |
Live Load |
Total Load |
Live Load |
Total Load |
Live Load |
Total Load |
Live Load |
Total Load |
Live Load |
Total Load |
Live Load |
Total Load |
Live Load |
Total Load |
| 6 |
|
350 |
|
386 |
|
386 |
|
386 |
|
362 |
|
412 |
|
412 |
|
412 |
| 7 |
|
302 |
|
332 |
|
332 |
|
332 |
|
312 |
|
355 |
|
355 |
|
355 |
| 8 |
|
265 |
|
292 |
|
292 |
|
292 |
|
274 |
|
311 |
|
311 |
|
311 |
| 9 |
|
236 |
|
260 |
|
260 |
|
260 |
|
244 |
|
278 |
|
278 |
|
278 |
| 10 |
183 |
202 |
|
235 |
|
235 |
|
235 |
|
220 |
|
250 |
|
250 |
|
250 |
| 11 |
143 |
168 |
|
214 |
|
214 |
|
214 |
|
201 |
|
228 |
|
228 |
|
228 |
| 12 |
113 |
142 |
184 |
189 |
|
196 |
|
196 |
173 |
184 |
|
209 |
|
209 |
|
209 |
| 13 |
91 |
121 |
149 |
162 |
|
182 |
|
182 |
141 |
170 |
|
194 |
|
194 |
|
194 |
| 14 |
75 |
105 |
122 |
140 |
|
169 |
|
169 |
116 |
158 |
|
180 |
|
180 |
|
180 |
| 15 |
62 |
91 |
102 |
122 |
|
158 |
|
158 |
96 |
148 |
156 |
168 |
|
168 |
|
168 |
| 16 |
51 |
80 |
85 |
107 |
143 |
148 |
|
148 |
81 |
139 |
131 |
158 |
|
158 |
|
158 |
| 17 |
43 |
71 |
72 |
95 |
122 |
139 |
|
139 |
69 |
131 |
112 |
149 |
|
149 |
|
149 |
| 18 |
37 |
64 |
61 |
85 |
104 |
132 |
|
132 |
59 |
118 |
96 |
141 |
137 |
141 |
|
141 |
| 19 |
32 |
57 |
53 |
76 |
90 |
125 |
120 |
125 |
51 |
101 |
83 |
133 |
118 |
133 |
|
133 |
| 20 |
27 |
52 |
46 |
69 |
78 |
119 |
105 |
119 |
44 |
88 |
72 |
127 |
103 |
127 |
|
127 |
| 21 |
|
|
40 |
63 |
68 |
113 |
91 |
113 |
38 |
76 |
63 |
121 |
90 |
121 |
120 |
121 |
| 22 |
|
|
35 |
57 |
60 |
104 |
80 |
108 |
34 |
67 |
55 |
111 |
80 |
115 |
106 |
115 |
| 23 |
|
|
31 |
52 |
53 |
95 |
71 |
103 |
30 |
59 |
49 |
98 |
70 |
110 |
94 |
110 |
| 24 |
|
|
27 |
48 |
47 |
87 |
63 |
99 |
26 |
52 |
43 |
87 |
63 |
106 |
84 |
106 |
| 26 |
|
|
|
|
37 |
75 |
50 |
88 |
|
|
35 |
69 |
50 |
98 |
67 |
98 |
| 28 |
|
|
|
|
30 |
60 |
41 |
76 |
|
|
28 |
56 |
41 |
81 |
54 |
91 |
| |
SJ-55
Floor Load Table Allowable Load in
Pounds per Lineal Foot |
| Span (ft) |
11-7/8"
|
14"
|
16"
|
| Live Load |
Total Load |
Live Load |
Total Load |
Live Load |
Total Load |
| 6 |
|
450 |
|
450 |
|
450 |
| 7 |
|
388 |
|
388 |
|
388 |
| 8 |
|
341 |
|
341 |
|
341 |
| 9 |
|
304 |
|
304 |
|
304 |
| 10 |
|
274 |
|
274 |
|
274 |
| 11 |
|
250 |
|
250 |
|
250 |
| 12 |
|
229 |
|
229 |
|
229 |
| 13 |
|
212 |
|
212 |
|
212 |
| 14 |
|
197 |
|
197 |
|
197 |
| 15 |
178 |
184 |
|
184 |
|
184 |
| 16 |
150 |
173 |
|
173 |
|
173 |
| 17 |
128 |
163 |
|
163 |
|
163 |
| 18 |
109 |
154 |
|
154 |
|
154 |
| 19 |
94 |
146 |
135 |
146 |
|
146 |
| 20 |
82 |
138 |
117 |
138 |
|
138 |
| 21 |
71 |
132 |
102 |
132 |
|
132 |
| 22 |
63 |
125 |
90 |
126 |
120 |
126 |
| 23 |
55 |
110 |
80 |
121 |
106 |
121 |
| 24 |
49 |
98 |
71 |
116 |
95 |
116 |
| 26 |
39 |
78 |
56 |
107 |
76 |
107 |
| 28 |
32 |
63 |
46 |
91 |
61 |
99 |
Notes:
- Total load values are based on joist spacing of 24" oc
or less (repetitive member). Table values are for single joist use only; multiple joists
should be evaluated using design properties.
- Live load values are based on limiting deflection to L/480.
Total load values are based on limiting deflection to L/240. If live load is not shown,
then total load deflection is equal to or better than L/480.
- Both total load and live load must be considered for proper
joist selection.
- Spans are based on clear distance between supports.
- Allowable loads shown may be used for simple or multiple
spans. Outermost spans in multiple span applications must be at least 40% of adjacent
span.
- Bearing stiffeners are required at interior supports
of multiple span applications.
- Contact Willamette Technical Support at 1-800-942-9927 for
applications with holes.
| Please see the SJ-32 SJ-42 SJ-55 Installation
Guide for additional information. |
|
Copyright © 19962008 AECinfo.com
|
|