| Search |
|
|
|
| |
| Site Navigation |
|
|
|
| News / Publications |
|
|
|
| Jobs | |
|
|
| Service |
|
|
|
|
|


|
| |
|
| |
Willamette StrucJoist SJ-32-42-55 StrucJoist SJ-32-42-55 - Page 36
| 2.0E StrucLam Floor 100% Load Tablee Allowable uniform loads (In pounds per lineal foot) |
| |
See Note 1. |
| Span(Ft.) |
One-1-3/4"
X 7-1/4" |
One-1-3/4"
x 9-1/4" |
One-1-3/4"
x 9-1/2" |
One-1-3/4"
x 11-1/4" |
One-1-3/4"
x 11-7/8" |
One-1-3/4"
x 14" |
One-1-3/4"
x 16" |
One-1-3/4"
x 18" |
| Live Load L/360 |
Total Load L/240 |
Live Load L/360 |
Total Load L/240 |
Live Load L/360 |
Total Load L/240 |
Live Load L/360 |
Total Load L/240 |
Live Load L/360 |
Total Load L/240 |
Live Load L/360 |
Total Load L/240 |
Live Load L/360 |
Total Load L/240 |
Live Load L/360 |
Total Load L/240 |
| 6 |
682 |
766 |
1033 |
1033 |
|
1068 |
|
1330 |
|
1430 |
|
1802 |
|
2201 |
|
2660 |
| 8 |
306 |
459 |
600 |
727 |
649 |
751 |
|
921 |
|
984 |
|
1214 |
|
1451 |
|
1710 |
| 10 |
161 |
242 |
322 |
483 |
349 |
523 |
559 |
704 |
648 |
751 |
|
916 |
|
1082 |
|
1260 |
| 12 |
95 |
142 |
191 |
287 |
207 |
311 |
335 |
503 |
390 |
563 |
617 |
735 |
|
863 |
|
998 |
| 14 |
60 |
91 |
122 |
183 |
133 |
199 |
216 |
324 |
252 |
378 |
402 |
562 |
583 |
717 |
805 |
826 |
| 16 |
41 |
61 |
83 |
124 |
90 |
135 |
147 |
221 |
172 |
258 |
276 |
413 |
402 |
552 |
559 |
688 |
| 18 |
|
|
59 |
88 |
64 |
95 |
104 |
157 |
122 |
183 |
197 |
295 |
288 |
432 |
402 |
543 |
| 20 |
|
|
43 |
64 |
47 |
70 |
77 |
115 |
90 |
135 |
145 |
218 |
213 |
320 |
299 |
440 |
| 22 |
|
|
|
|
|
|
58 |
87 |
68 |
102 |
110 |
165 |
162 |
243 |
228 |
341 |
| 24 |
|
|
|
|
|
|
45 |
67 |
53 |
79 |
85 |
128 |
126 |
189 |
177 |
266 |
| 26 |
|
|
|
|
|
|
|
|
41 |
62 |
67 |
101 |
100 |
149 |
141 |
211 |
| 28 |
|
|
|
|
|
|
|
|
|
|
54 |
81 |
80 |
120 |
113 |
170 |
| 30 |
|
|
|
|
|
|
|
|
|
|
44 |
66 |
66 |
98 |
93 |
139 |
| 1.8E StrucLam Floor 100% Load Tablee Allowable uniform loads (In pounds per lineal foot) |
| |
See Note 1. |
| Span(Ft.) |
One-1-3/4"
X 7-1/4" |
One-1-3/4"
x 9-1/4" |
One-1-3/4"
x 9-1/2" |
One-1-3/4"
x 11-1/4" |
One-1-3/4"
x 11-7/8" |
One-1-3/4"
x 14" |
One-1-3/4"
x 16" |
One-1-3/4"
x 18" |
| Live Load L/360 |
Total Load L/240 |
Live Load L/360 |
Total Load L/240 |
Live Load L/360 |
Total Load L/240 |
Live Load L/360 |
Total Load L/240 |
Live Load L/360 |
Total Load L/240 |
Live Load L/360 |
Total Load L/240 |
Live Load L/360 |
Total Load L/240 |
Live Load L/360 |
Total Load L/240 |
| 6 |
616 |
766 |
1033 |
1033 |
|
1068 |
|
1330 |
|
1430 |
|
1802 |
|
2201 |
|
2660 |
| 8 |
276 |
415 |
540 |
700 |
581 |
736 |
920 |
921 |
|
984 |
|
1214 |
|
1451 |
|
1710 |
| 10 |
146 |
219 |
289 |
434 |
312 |
468 |
502 |
645 |
581 |
714 |
907 |
916 |
|
1082 |
|
1260 |
| 12 |
86 |
129 |
172 |
258 |
186 |
278 |
302 |
448 |
350 |
496 |
554 |
674 |
796 |
863 |
|
998 |
| 14 |
55 |
82 |
110 |
165 |
119 |
178 |
194 |
292 |
226 |
339 |
361 |
495 |
523 |
635 |
722 |
792 |
| 16 |
|
|
74 |
112 |
81 |
121 |
132 |
198 |
154 |
231 |
247 |
371 |
361 |
487 |
502 |
606 |
| 18 |
|
|
53 |
79 |
57 |
85 |
94 |
141 |
109 |
164 |
177 |
265 |
259 |
384 |
361 |
479 |
| 20 |
|
|
|
|
42 |
63 |
69 |
103 |
80 |
121 |
130 |
195 |
191 |
287 |
268 |
388 |
| 22 |
|
|
|
|
|
|
52 |
78 |
61 |
91 |
99 |
148 |
145 |
218 |
204 |
307 |
| 24 |
|
|
|
|
|
|
40 |
60 |
47 |
71 |
77 |
115 |
113 |
169 |
159 |
239 |
| 26 |
|
|
|
|
|
|
|
|
|
|
61 |
91 |
89 |
134 |
126 |
189 |
| 28 |
|
|
|
|
|
|
|
|
|
|
49 |
73 |
72 |
108 |
102 |
153 |
| 30 |
|
|
|
|
|
|
|
|
|
|
40 |
60 |
59 |
88 |
83 |
125 |
16" and 18" deep beams are limited
to two and three piece beams (single members are not permitted).
Table values are based on uniform loads and
the most restrictive of simple or continuous span. Shaded areas represent load conditions
controlled by a continuous span. When properly fastened together, double the table values
for two piece beams or triple the values for three piece beams. Reference inside front
cover for connection requirements.
Beams must be checked for stresses under
total load and for deflections for both live load and total load conditions. Design loads
must be in accordance with the applicable code. Deflections must not exceed the maximums
permitted by the code. If deflection limits other than those on which the tables are based
are applicable, beams must be designed using the StrucLam Design Stresses on the inside
front cover of this guide.
Table values assume continuous lateral
support of the compression edge of the beam and lateral support at the ends and all
bearing points.
Reference the bearing length chart on back
of product guide for required bearing length.
Please see the StrucLam
Installation Guide for additional information. |
Copyright © 19962008 AECinfo.com
|
|