Willamette StrucJoist SJ-32-42-55 StrucJoist SJ-32-42-55 - Page 37
| StrucLam Hangers 
Top
Mount - Single Member Hanger |
| Header |
Hanger |
| Single 1-3/4" x 9-1/4" Single 1-3/4" x 9-1/2"
Single 1-3/4" x 11-1/4"
Single 1-3/4" x 11-7/8"
Single 1-3/4" x 14 |
WP9.25 WP9
WP11.25
WP11
WP14 |

| Face Mount - Single Member
Hanger |
| Header |
Hanger |
| Single 1-3/4" x 9-1/4" Single 1-3/4" x 9-1/2"
Single 1-3/4" x 11-1/4"
Single 1-3/4" x 11-7/8"
Single 1-3/4" x 14 |
HU9 HU9
HU11
HU11
HU14 |

| Top Mount - Double Member
Hanger |
| Header |
Hanger |
| Double 1-3/4" x 9-1/4" Double 1-3/4" x 9-1/2"
Double 1-3/4" x 11-1/4"
Double 1-3/4" x 11-7/8"
Double 1-3/4" x 14
Double 1-3/4" x 16
Double 1-3/4" x 18 |
GLTV 3.56/9.25 GLTV 3.59
GLTV 3.56/11.25
GLTV 3.511
HGLTV 3.514
HGLTV 3.516
HGLTV 3.518 |

| Face Mount - Double Member
Hanger |
| Header |
Hanger |
| Double 1-3/4" x 9-1/4" Double 1-3/4" x 9-1/2"
Double 1-3/4" x 11-1/4"
Double 1-3/4" x 11-7/8"
Double 1-3/4" x 14
Double 1-3/4" x 16
Double 1-3/4" x 18 |
HGUS410 HGUS410
HGUS412
HGUS412
HGUS414
HGUS414
HGUS414 |

| Top Mount Triple Member
Hanger |
| Header |
Hanger |
| Triple 1-3/4" x 9-1/4" Triple 1-3/4" x 9-1/2"
Triple 1-3/4" x 11-1/4"
Triple 1-3/4" x 11-7/8"
Triple 1-3/4" x 14
Triple 1-3/4" x 16
Triple 1-3/4" x 18 |
HGLTV 5.50/9.25 HGLTV 5.59
HGLTV 5.50/11.25
HGLTV 5.511
HGLTV 5.514
HGLTV 5.516
HGLTV 5.518 |

| Face Mount -Triple Member
Hanger |
| Header |
Hanger |
| Triple 1-3/4" x 9-1/4" Triple 1-3/4" x 9-1/2"
Triple 1-3/4" x 11-1/4"
Triple 1-3/4" x 11-7/8"
Triple 1-3/4" x 14
Triple 1-3/4" x 16
Triple 1-3/4" x 18 |
HGUS 5.50/10 HGUS 5.50/10
HGUS 5.50/12
HGUS 5.50/12
HGUS 5.50/14
HGUS 5.50/14
HGUS 5.50/14 |
Notes:
- Hanger capacities may be less than the StrucLam LVL
capacity. Therefore all applications need to be checked to verify adequate hanger
capacity.
- Hanger capacity depends on the hanger selected, quantity and
size of nails used and the size and type of support to which it is fastened. Please refer
to hanger manufacturer's literature for capacities, installation requirements and
alternative hangers.
- Fill all nail holes with proper nails. Full bearing required
at hanger seat.
- The specifications above are for Simpson Strong-Tie hangers.
| StrucLam LVL Bearing Length (inches) |
| Reaction (Ibs.) |
Beam
Width |
Reaction (lbs.) |
Beam
Width |
| 1-3/4" |
3-1/2" |
5-1/4" |
7" |
1-3/4" |
3-1/2" |
5-1/4" |
7" |
| 1,000 |
1.50 |
1.50 |
1.50 |
1.50 |
15,000 |
|
|
4.25 |
3.25 |
| 2,000 |
1.75 |
1.50 |
1.50 |
1.50 |
16,000 |
|
|
4.50 |
3.50 |
| 3,000 |
2.50 |
1.50 |
1.50 |
1.50 |
17,000 |
|
|
4.75 |
3.50 |
| 4,000 |
3.50 |
1.75 |
1.50 |
1.50 |
18,000 |
|
|
5.00 |
3.75 |
| 5,000 |
4.25 |
2.25 |
1.50 |
1.50 |
19,000 |
|
|
5.25 |
4.00 |
| 6,000 |
5.00 |
2.50 |
1.75 |
1.50 |
20,000 |
|
|
5.50 |
4.25 |
| 7,000 |
5.75 |
3.00 |
2.00 |
1.50 |
21,000 |
|
|
5.75 |
4.50 |
| 8,000 |
|
3.50 |
2.25 |
1.75 |
22,000 |
|
|
|
4.50 |
| 9,000 |
|
3.75 |
2.50 |
2.00 |
23,000 |
|
|
|
4.75 |
| 10,000 |
|
4.25 |
2.75 |
2.25 |
24,000 |
|
|
|
5.00 |
| 11,000 |
|
4.50 |
3.00 |
2.25 |
25,000 |
|
|
|
5.25 |
| 12,000 |
|
5.00 |
3.50 |
2.50 |
26,000 |
|
|
|
5.50 |
| 13,000 |
|
5.50 |
3.75 |
2.75 |
27,000 |
|
|
|
5.75 |
| 14.000 |
|
5.75 |
4.00 |
3.00 |
28,000 |
|
|
|
5.75 |
- Minimum bearing length is 1-1/2".
- Bearing across the full width of the beam is required.
- Bearing lengths are based on 700 psi. Bearing length must be
adjusted when allowable bearing stress of support member is less than 700 psi.
- Structural adequacy of supporting member is assumed.
Adjusted bearing length example
Table value = 700 psi
Fc l = 625 psi (Doug-fir species wall plate)
Ratio = 700/625 = 1.12
| Example from table: |
Reaction = 10,000# |
|
Beam width - 5-1/4" (3 ply
LVL) |
|
Required bearing =
2.75" |
Adjusted bearing on Doug-fir species stud wall plates.
2.75 x 1.12 = 3.08" |