Table 3

FASTENER SCHEDULE AND DESIGN LOAD ( Ibs / ft ) FOR MULTIPLE PLIES OF 1-3/4-INCH STRUCLAM LVL1,2,3

 

No. of Piles

Nailed Connection4,6 Through Bolted Connection5
2 rows 16d common wire at 12 inches on center 3 rows 16d common wire at 12inches on center 2 rows 1/2 inch bolts at 24 inches on center, staggered 2 rows 1/2 inch bolts at 12 inches on center, staggered 2 rows 1/2inch bolts at 6 inches on center, staggered
2

3

505

380

760

570

505

380

1010

760

2020

1520

4 Not Applicable Shall only be used when loads are applied to "both" sides of the members.
335 670 1340

For Sl: 1 inch = 25.4 mm, 1 lbf/ft = 14.6 N/m

REQUIREMENTS:

  1. StrucLam thickness shall be 1-3/4 inches (44.4 mm).
  2. Design load shall be the maximum load applied to the outside ply .
  3. Values listed above are based on a normal duration load. For other durations, the load shall be adjusted in accordance with the applicable code.
  4. For a three ply member, the nailing specified shall be applied to both sides of member .
  5. Bolt holes shall be a minimum of 1/32-inch (.8 mm) to a maximum of 1/16-inch (1.6 mm) larger than the bolt diameter , and shall be located a minimum of 2-inches (50.8 mm) from the top or bottom of the beam, parallel to the direction of load.

For nailed members, see detail B6 of Figure 1 of this report for depth requirements.

Table 4

StrucLam LVL Bearing Length (inches)

Reaction

(Ibs.)

Beam Width (inches) Reaction

(lbs.)

Beam Width (inches)
1-3/4" 3-1/2" 5-1/4" 7" 1-3/4" 3-1/2" 5-1/4" 7"
1,000 1.50 1.50 1.50 1.50 15,000 -- -- 4.25 3.25
2,000 1.75 1.50 1.50 1.50 16,000 -- -- 4.50 3.50
3,000 2.50 1.50 1.50 1.50 17,000 -- -- 4.75 3.50
4,000 3.50 1.75 1.50 1.50 18,000 -- -- 5.00 3.75
5,000 4.25 2.25 1.50 1.50 19,000 -- -- 5.25 4.00
6,000 5.00 2.50 1.75 1.50 20,000 -- -- 5.50 4.25
7,000 5.75 3.00 2.00 1.50 21,000 -- -- 5.75 4.50
8,000 -- 3.50 2.25 1.75 22,000 -- -- -- 4.50
9,000 -- 3.75 2.50 2.00 23,000 -- -- -- 4.75
10,000 -- 4.25 2.75 2.25 24,000 -- -- -- 5.00
11,000 -- 4.50 3.00 2.25 25,000 -- -- -- 5.25
12,000 -- 5.00 3.50 2.50 26,000 -- -- -- 5.50
13,000 -- 5.50 3.75 2.75 27,000 --   -- 5.75
14.000 -- 5.75 4.00 3.00 28,000 -- -- -- 5.75

For Sl: 1 inch = 25.4 mm, 1 lbf = 4.45 N, 1 psi = 6.89 kPa

NOTES:

  1. Bearing length shall not be less than 1-1/2 inches (38.1 mm).
  2. Bearing across the full width of the beam is required.
  3. Bearing lengths shown are based on an allowable bearing stress of 700 psi (4823 Kpa). Bearing length shall be increased proportionally when the allowable bearing stress of the support member is less than 700 psi (4823 Kpa).

Request for Information / Request a Catalog from Willamette
 
 
 
To request more information from Willamette, please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com