| Installation All 3320 and 3520 Series Holder/Stop closures, either individually
sized or multisized, combine a full feature 3000 Series door closer with an exceptionally
sturdy arm assembly that provides a positive stop and is optionally available with a
hold-open feature.
The door closer's backcheck feature slows the door before
it reaches its fully open position. A bracket on the arm's soffit plate then furnishes a
positive stop for the door. When hold-open is required it is available with either a
hex-key or thumbturn control feature.
Door Sizing Sized Closers
| MAXIMUM
DOOR SIZE FT.IN. (METERS) |
CLOSER
SIZE* |
| INTERIOR |
EXTERIOR |
2'6''
(0.75) |
- |
3322
3522 |
3'0''
(0.90) |
2'6''
(0.75) |
3323
3523 |
3'6''
(1.05) |
3'0''
(0.90) |
3324
3524 |
4.0''
(1.20) |
3'6''
(1.05) |
3325
3525 |
-
- |
4'0''
(1.20) |
3326
3526 |
*Size Based on standard weight and size (7'0'') door hung
on ball bearing hinges. Larger doors or doors exposed to severe winds or drafts usually
require the next size closer.


#With Full Metal Cover this dimension is 6-1/4'' (159mm).
TYPICAL POWER ADJUSTMENTS* MULTI-SIZE CLOSERS
MAXIMUM
DOOR SIZE FT.IN. (METERS) |
+NUMBER
OF TURNS (360°) OF ADJUSTMENT NUT |
| INTERIOR |
EXTERIOR |
| NORMAL POWER
CLOSERS
(1)
|
2'6''
(0.75) |
2 |
3 |
3'0''
(0.90) |
3 |
5 |
3'6''
(1.05) |
5 |
7 |
4.0''
(1.20) |
7 |
9 |
+Maximum No. of 360° Turns
12 |
BARRIER CODE POWER RANGE CLOSERS
(2) |
2'6''
(0.75) |
3 |
8 |
3'0''
(0.90) |
3 |
8 |
3'6''
(1.05) |
4 |
9 |
4.0''
(1.20) |
6 |
11 |
| +Maximum No. of 360° Turns
15 |
*Chart shows typical adjustment only. Installer must adjust
the closer for proper control based upon individual installation configuration and
environment. Each closer is packed with a chart to guide proper adjustment based upon type
of installation and size of door.
- Power of closer can be adjusted to conform to the sizing
requirements outlined in ANSI A156.4-1980, Standards For Door Controls - Closers.
- Power of closer can be adjusted to conform to the sizing
requirements outlined in A.D.A. and ANSI A117.1 -1980, Specifications For Making Buildings
and Facilities Accessible To And Usable By Physically Handicapped People.
|