 400 POWER TRACK
PULL (HINGE) SIDE MOUNTING
Master Unit Controlled by Integral Smoke Detector
Series 400PTD Slave Unit Controlled by Master Unit Smoke Detector Series 400PTS Support
Unit Controlled by Remote Detection Equipment Series 400PT
Door Closer Features
400 Series Door Closer is a modern,
non-handed narrow projection closer with 50% spring power adjustment. It has four
independent non-critical regulating valves to control closing speed, latch speed,
backcheck cushioning and backcheck position.
Single Door
(1) 400PTD Master Unit with Integral Smoke
Detector or
(1) 400PT Support Unit by Remote Detection
Equipment.
Pair of Doors
(1) 400PTD Master Unit with Integral Smoke
Detector controlling
(1) 400PTS Slave Unit.
(1) 400PTD Master Unit with Integral smoke
Detector reporting to Alarm Panel and
(1) 400PT Support Unit. Both Master Unit
Solenoid and Support Unit Solenoid controlled by Alarm Panel.
(2) 400 PT Support Units controlled by
Remote Detection Equipment.
Installation Details


Double Egress Doors
With reveals greaten than 1/8" (3mm); a special handed
arm for the Pull (Hinge) Side Power Track; accommodates reveals to 3" (76mm). Suffix
"DE" to the List Number and specify hand, i.e. 400PTD-DE 120 x RH.
Arms

Door Size, Opening & Applicable Units
| |
DOOR(S)
OPENING FT.-IN. (METERS) |
YALE
LIST NUMBER & TYPE OF UNIT |
| MAX.* |
MIN.** |
| SINGLE |
4' - 0"
(1.2) |
3' - 0"
(0.9) |
(1) 400PTD -
MASTER |
| 4' - 0"
(1.2) |
2' - 8"
(0.8) |
(1) 400PT -
SUPPORT |
| PAIR |
4' -
0" (1.2) |
4' -
0" (1.2) |
(1) 400PTD -
MASTER & (1) 400PTS - SLAVE |
| (1) 400PTD -
MASTER & (1) 400PT - SUPPORT |
| 8' - 0"
(2.4) |
5' - 4"
(1.6) |
(2) 400PT -
SUPPORT |
*Maximum door size for door closer power.
**Minimum door opening for standard Power Track
installations. Consult factory for door openings narrower than those shown.
Door Closer: mounts to the door's top
rail; 3-5/8" (92mm) minimum top rail; 2-3/4" (70mm), with #486 Drop Plate.
Power Track: mounts on the frame face;
2" (51mm) minimum ceiling clearance.

|