   Yale Security Inc.  400-3000 Series Power Track Closer Holders  

400/3000 Series Power Track - Page 15

 

 

Yale Security Inc.

ORDERING POWER TRACK VOLTAGES

Ordering Power Track Voltage(s)

TYPE OF UNIT MODEL POWER INPUT DATA (CAN BE) USED WITH
NO. OF POWER INPUT LINES* CHOICES OF VOLTAGE INPUT
MASTER PTD - 24 1 24 VOLTS AC/DC SLAVE MODEL PTS
PTD - 120 1 120 VOLT AC, 60HZ SLAVE MODEL PTS
PTD- 24DX120 2 24 VOLTS AC/DC TO POWER SMOKE DETECTOR 120 BOLT AC, 60 HZ, TO POWER SOLENOID SUPPORT MODEL PT120
SLAVE PTS 1 POWER SUPPLIED FROM MASTER UNIT (24VDC) MASTER MODEL PTD-24 OR MASTER MODEL PTD-120
SUPPORT PT - 24 1 24 VOLT  AC/DC AREA SMOKE DETECTION SYSTEM
PT - 120 1 120 VOLT AC, 60 HZ AREA SMOKE DETECTION SYSTEM OR MASTER MODEL PTD24-120
EXECUTIVE PT - RF 1 120 VOLT AC, 60HZ N/A

*Pairs of input lines required to supply Operating Voltage or Voltages to the unit. Pairs listed do not include  signal wires to Alarm panels not control wires to other units' solenoids.

Operating Voltage or Voltages for the control of fire/smoke doors are specified by the architect, electrical engineer and alarm system engineer and /or contractor. Consulting with these sources will verify which operating voltage(s) should be ordered.

"PTD" Master Units have two components which require electrical power; the Integral Smoke Detector will always require 24VDC input power; the Hold-Open Solenoid can require either 24VDC input or 120VDC input. A third component, the hook-up box, receives all primary voltage inputs and distributes them to the smoke detector and the hold open solenoid.

"PTD" Master Units are available with three voltage options:

With PTD-24 suffix - unit will accept either 24VAC or 24VDC power input,. A rectifier in the hook-up box will rectify alternating current to direct current for operation of both the smoke dete4ctor and hold-open solenoid.

With PTD-120 suffix - Unit will accept 120VAC power input. A 120VAC to 24VAC transformer in the hook-up box steps the input voltage down to 24VAC. It is then rectified to 24VDC for operation of both the smoke detector and the hold-open solenoid.

"PTD" Master Units Voltage Options (cont.)

With PTD-24D x 120 suffix - Unit must receive 24VAC or 24VDC power input . A rectifier in the hook-up box will rectify alternating current to direct current for operation of the smoke detector. Unit must also receive a 120VAC power input from a separate circuit. It is then rectified in the hook-up box to 120VDC to operate the hold-open solenoid.

Slave Units (PTS suffix) have only a hold-open solenoid which requires electrical power. They are only available with an operating voltage of 24VDC since they are only installed when they are controlled directly by the integral Smoke Detector of the Master Unit.

Support Units (PT-24 or PT-120 suffix) similarly have only a hold-open solenoid which requires electrical power. These solenoids are controlled by Smoke Detection Equipment or remote Alarm Panels. They can be ordered for operation on 24 Volt AC/DC or 120VAC, 60Hz. Support units (PT-24 or PT-120 suffixes) have their hold-open solenoid operating on direct current. They have built -in rectifier that converts alternating current to direct current.

*Request for Information / Request a Catalog
 
 
 
To request more information from Yale Security Inc., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free bi-monthly AECnews e-Newsletter.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996-2008 AECinfo.com