 4220/4230 SERIES SUPPORT UNITS
Push (Stop) Side Mounting Double Lever Arm
Units Controlled Remotely by Area/Ceiling Detectors
Support Unit Series 4220MPI/4230MPI: Infinite
Hold-Open
Support Unit Series 4220MPS/4230MPS: Selective Hold-Open

These Closer-Holders are surface mounted to the Push (stop)
side frame face. The standard mounting for these units require a minimum ceiling clearance
of 3-1/2" (89mm). Where ceiling clearance is between 2" and 3-1/2" (51mm
and 89mm) , the standard backplate for the 4220 Series or 4230 Series can be inverted to
allow for a drop application. Use of a No. 4298 decorative backplate is recommended to
conceal the exposed mounting holes on the standard backplate. Different mounting
dimensions are required for the drop application. The double lever arm mounts directly to
the door,. These units can be installed to accommodate door openings to 180º with a 170º
maximum hold-open point.
The Series 4220MPI/4230MPI and 4220MPS/4230MPS, with double
lever arm, are intended for use with compatible U.L. listed detection equipment.


Door Sizes and List Numbers
| MAXIMUM* DOOR SIZE
FT.IN. (METERS) |
YALE LIST NUMBER |
MAXIMUM DEGREE OF
DOOR OPENING |
REVEAL RANGE
INCHES (MILLIMETERS) |
| INFINITE HOLD-OPEN |
SELECTIVE HOLD-OPEN |
| 3"-6" (1.10) |
4223MPI |
4223MPS |
180º |
2-3/4-4 (70-102) |
| 165º |
4-7 (102-179) |
| 4233MPI |
4233MPS |
180º |
4-7 (102-179) |
| 4"-0"(1.20) |
4224MPI |
4224MPS |
180º |
2-3/4-4 (70-102) |
| 165º |
4-7 (102-179) |
| 4234MPI |
4234MPS |
180º |
4-7 (102-179) |
Electrical Data
| SUPPORT UNIT LIST NUMBER |
NUMBER POWER INPUT LINES* (PAIRS) |
OPERATING VOLTAGE (INPUT) |
AMPERAGE DRAW SOLENOID COIL (AMPERES) |
(CAN BE) USED IN CONJUNCTION WITH |
| 4220MPI-24 4230MPI-24 |
1 |
24VAC/DC |
.070 @ 24VAC/DC |
COMPATIBLE SMOKE
DETECTION EQUIPMENT |
| 4220MPS-24 4230MPS-24 |
| 4220MPI-120 4230MPI-120 |
1 |
120VAC |
.035 @ 120VAC |
COMPATIBLE SMOKE DETECTION
EQUIPMENT |
| 4220MPS-120 4230MPS-120 |
Maximum / Minimum Operating Voltage Parameters: = 10%; -15% |