   Yale Security Inc.  4500/4500DPS Overhead Concealed Door Closer  

Overhead Concealed Door Closer - Page4

 

 

Yale Security Inc.

4500 OFFSET PIVOT INSTALLATION

4500-OP/ 4510-OP Series Installations

Removable frame stop by others is required for this application.

Non-Hold Open (See sizing charts on page 3.)

Degree of Door Opening 85° to 120° 3 121° to 180° 4
Length of Slide Track1 25
(0.64m)
21
(0.53m)
25
(0.64m)
Minimum Door Width 30
(0.76m)
27
(0.69m)
28
(0.71m)
Template Position of Slide Track2 "G" 3-7/8
(98)
1
(25)

Hold Open (See sizing charts on page 3.)

Hold Open Point 85° 90° 95° 100°
Length of Slide Track1 25
(0.64m)
21
(0.53m)
25
(0.64m)
22
(0.56m)
25
(0.64m)
22
(0.56m)
25
(0.64m)
23
(0.58m)
Minimum Door Width 33
(0.84m)
29
(0.74m)
33
(0.84m)
29
(0.74m)
32
(0.81m)
29
(0.74m)
31
(0.79m)
29
(0.74m)
Template Position of Slide Track2  "G" 6-1/2
(165)
5-3/4
(146)
5
(127)
4-1/4
(108)

 

Hold Open Point 105° 5 110° 5 115° 5 120° 5 125° 5
Length of Slide Track1 25 (0.64m) 24
(0.61m)
25
(0.64m)
24
(0.61m)
25
(0.64m)
24
(0.61m)
25
(0.64m)
25
(0.64m)
Minimum Door Width 30 (0.76m) 28
(0.71m)
29
(0.74m)
28
(0.71m)
29
(0.74m)
28
(0.71m)
28
(0.71m)
28
(0.71m)
Template Position of Slide Track2 "G" 3-5/8
(92)
3
(76)
2-5/8
(67)
2-1/8
(54)
1-3/4
(44)

Notes:

  1. All Yale 4500 Series Closers are supplied with a slide 25 (635) long. For narrow doors a shorter length slide track is required. The track can be cut to required length at the time of installation. This provides application versatility and assures the proper length track.
  2. The template position for the slide track must always be measured from the centerline of the door's pivot point.
  3. An auxiliary door stop is required for door openings beyond 105°. Use of an auxiliary door stop is always recommended.
  4. To obtain door openings between 120° and 180°, an intermediate pivot must be used in lieu of a conventional top pivot. An auxiliary door stop would then be required for door openings beyond 110°. Use of an auxiliary door stop is always recommended.
  5. To obtain hold open points between 105° and 125°, an intermediate pivot must be used in lieu of a conventional top pivot.

Dimensions are given in inches (mm) unless otherwise noted

Request for Information / Request a Catalog from Yale Security Inc.
 
 
 
To request more information from Yale Security Inc., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com