| Search |
|
|
|
| |
| Site Navigation |
|
|
|
| News / Publications |
|
|
|
| Jobs | |
|
|
| Service |
|
|
|
|
|


|
| |
|
| |
Yale Security Inc. 4500/4500DPS Overhead Concealed Door Closer Overhead Concealed Door Closer - Page4
 4500 OFFSET PIVOT INSTALLATION
| 4500-OP/ 4510-OP Series Installations 
|
Removable frame stop by others is required for
this application. |
Non-Hold Open (See
sizing charts on page 3.)
| Degree
of Door Opening |
85°
to 120° 3 |
121°
to 180° 4 |
| Length
of Slide Track1 |
25
(0.64m) |
21
(0.53m) |
25
(0.64m) |
| Minimum
Door Width |
30
(0.76m) |
27
(0.69m) |
28
(0.71m) |
| Template
Position of Slide Track2 "G" |
3-7/8
(98) |
1
(25) |
Hold Open (See sizing charts on page 3.)
| Hold
Open Point |
85° |
90° |
95° |
100° |
| Length
of Slide Track1 |
25
(0.64m) |
21
(0.53m) |
25
(0.64m) |
22
(0.56m) |
25
(0.64m) |
22
(0.56m) |
25
(0.64m) |
23
(0.58m) |
| Minimum
Door Width |
33
(0.84m) |
29
(0.74m) |
33
(0.84m) |
29
(0.74m) |
32
(0.81m) |
29
(0.74m) |
31
(0.79m) |
29
(0.74m) |
| Template
Position of Slide Track2 "G" |
6-1/2
(165) |
5-3/4
(146) |
5
(127) |
4-1/4
(108) |
| Hold
Open Point |
105° 5 |
110° 5 |
115° 5 |
120°
5 |
125°
5 |
| Length
of Slide Track1 |
25
(0.64m) |
24
(0.61m) |
25
(0.64m) |
24
(0.61m) |
25
(0.64m) |
24
(0.61m) |
25
(0.64m) |
25
(0.64m) |
| Minimum
Door Width |
30
(0.76m) |
28
(0.71m) |
29
(0.74m) |
28
(0.71m) |
29
(0.74m) |
28
(0.71m) |
28
(0.71m) |
28
(0.71m) |
| Template
Position of Slide Track2 "G" |
3-5/8
(92) |
3
(76) |
2-5/8
(67) |
2-1/8
(54) |
1-3/4
(44) |
Notes:
- All Yale 4500 Series Closers are supplied with a slide 25
(635) long. For narrow doors a shorter length slide track is required. The track can be
cut to required length at the time of installation. This provides application versatility
and assures the proper length track.
- The template position for the slide track must always be
measured from the centerline of the door's pivot point.
- An auxiliary door stop is required for door openings beyond
105°. Use of an auxiliary door stop is always recommended.
- To obtain door openings between 120° and
180°, an intermediate pivot must be used in lieu of a conventional top
pivot. An auxiliary door stop would then be required for door openings beyond 110°. Use
of an auxiliary door stop is always recommended.
- To obtain hold open points between 105°
and 125°, an intermediate pivot must be used in lieu of a conventional
top pivot.
Dimensions are given in inches (mm) unless otherwise noted |
|
Copyright © 19962008 AECinfo.com
|
|