| Installation All 4500DPS Series closers are shipped with a slide track 25"
(635mm) long. For narrower doors a shorter length slide track is required. The track may
be cut to the desired length at the time of installation. This provides versatility and
assures proper length track. The template position for the slide track must always be
measured from the centerline of the door's pivot point.
Butt Hinge Installation: An auxiliary door
stop is required for openings beyond 110°. Minimum door width is 28" (711mm). The
track may have to be cut at the time of installation for hold open applications.
3/4" Offset Pivot Installation: An
auxiliary door stop is required for openings beyond 105°.
Non-Hold Open: Minimum door width is
27" (686mm) for 3/4" (1.9mm) off set hinges. Consult factory for openings
greater than 120°.
Hold Open: Minimum door width is 29"
(737mm) for desired hold open between 85° and 100°. Consult factory for hold open beyond
100°.
Installation Dimensions

"G" dimension depends on degree of door opening:
- Butt Hinge Installation dimensions, see page 4.
- Offset Pivot Installation dimensions, see page 5.
All dimensions are for reference only. Dimensions are given
in inches (mm) unless otherwise noted. Door sizing information is based on installation on
standard weight doors, 7' 0" (2.13m) high x 1-3/4" (44mm) thick; hung on
anti-friction hinges and operating normal conditions. |