A member of the Yale Security Group
Key controls can be furnished in any of these arrangements;
Keyed Alike (KA); Keyed Different(KD); Master Keyed (MK); Grand Master-Keyed(GMK); Great
Grand Master Keyed (GGMK); Construction Keying (CMK); Maison System.
Master Keying
There are several types of master key systems;
Simple Master Systems. Each lock has its
own individual key which will not operate any other lock in the system, but all locks in
the system can be operate by the master key.
Grand Master Systems. Each lock has its
own individual key as in the simple master key system and the locks are divided into two
or more groups, each group being operated by the Master Key, and all groups, or the entire
system, operated by the Grand Master Key.
Great Grand Master Systems (or
higher levels of keying). Each lock has its own individual key, and the locks are divided
into additional groups as needed including master keys and grand master keys with all
groups, or the entire system operated by the Great Grand Master-Key.
Most .51'' pin tumbler cylinders can be provided with
construction keying for use by architect or contractor personnel during building
construction. A special break-out key is used to permanently void the construction key.
This action eliminates further use of the construction or break-out key. Available
with all cylinder options. To order, suffix ''C'' to list number, i.e. 1801 CGMK.
Note: For further instructions contact you
authorized Yale distributor or your Yale Sales Agency.
RN411 Guest's Key for 5320 Lockset
Functions. Operates only the lock or locks of one room or suite, except if shut-out by
push button on inside knob.
FN411 Maid's Key. Maid's master key
operates one group of locks, generally the guest rooms except guest rooms shut-out by
push-button on inside knob and linen closet on one floor served by one maid.
FN411 Housekeeper's Key. House keeper's
master key operates a number of Maid's groups, generally the entire Guest Room portion,
when so specified, except Guest Rooms shut-out by push-button on inside knob.
FN411S Display Key. For Guest Rooms used
as sample rooms. Operates guest room when locked by shutout key from inside.
FN411 Grand Master Key. Operates locks
controlled by Maids, Housekeeper, Chef, Master Mechanic and other Master Keys, generally
all locks in the hotel except when Guest Rooms are shut-out by push-button on inside knob.
The Grand Master Key does not operate as an emergency/shut-out key.
FN411S Emergency Key. Operates all Guest
room locks even when they are locked from the inside.
Note: The Hotel/Motel Guest Room Key
System can be keyed and Master Keyed with cylindrical locks, Mono locks, mortise locks,
auxiliary locks, padlocks, and exit devices. This includes hotel mortise lock functions
using the 2719 cylinders. Cannot be keyed with 2196H hotel removable core mortise lock
cylinder.
1801 and 1801A Conventional Cylinders, 1210 and 1220
Removable Core Cylinders are available with a dust shield to protect the pin tumbler and
plug from the penetration of dust, and sand and other unusual environmental properties.
Not available for 1803 or 1801N cylinders. To order, specify lock/cylinder number and dust
guard.

|