 A member of the Yale Security Group
| ELECTRIFIED EXIT DEVICE ACCESSORIES |
7000 |
The 780 Power Supply provides 2amps of output current at
24VDC. It can control a total of 5 Electric Dogging Devices or "Safe" or
"Secure" Mortise Exit Devices. Separate switching devices (key switches or
pushbuttons) must be used to control locking devices in the circuit.
Specifications
- 120VAC Input Power
- 24VDC @ 2 Amp Output
- Fire Alarm Interface

9231 - (1) SPDT Maintained
9232 - (1) SPDT Momentary
Options:
- 1-3/4" Narrow face plate (suffix "N")
- L2 suffix - two LEDs (red and green)
Specifications;
- Keyswitch for operation using a standard 1-1/4" mortise
cylinder (Cylinder not included).
- Contact Rating 10 Amps @ 120VAC, or 28VDC.
- SPDT 3-position
The 781 Controller is designed to control one or two
electric Latch Pullback devices. Operation can be set for sequential or individual control
of doors. When using a momentary normally open contact switch, the latch pullback delay
time feature can be adjusted from 1 to 20 seconds, providing an put to interface with
automatic door operator controllers.
Listing
Listed as an Exit Device Control Unit to UL 294
requirements.
Specifications
120VAC 60HZ Power Input 14 Amp inrush for 100 milliseconds,
Holding voltage @ 28 volts .180 Amp

Circuit Wiring
Up to 40 feet: 16 AWG wire.
Up to 60 feet: 14 AWG wire.
Up to 100 feet: 12 AWG wire.
All wiring must be stranded.
| Push Button / Toggle Switch |

9411 - (1) SPDT Momentary
9412 - (1) SPDT Maintained (Alt. Action)
9511 - (1) SPDT Momentary
TS9271 - (1) SPDT Maintained
Option:
- L2 - two LEDs (red and green)
Specifications:
- SPDT form Z contact
- 9400 - Rated 6AMP @ 120VAC
- 9500 - Rated 12AMP @ 120VAC
- TS9271 SPDT 3 position - Rated 6AMP @ 120VAC
- 9500 Push button size - 1-9/16' (40mm) diameter.
| Audible/Visual Annunciators |

3271 - Sonalert 90Db @ 2ft. 12/24VDC
Mounted on one gang stainless steel plate.
3251-L2 - Two LEDs mounted on one gang stainless steel
plate. 12/24VDC (red and green) |