| 7100 & 7200 SERIES EXIT DEVICE
ALARM |

Activation: Alarm is armed by
turning key clockwise. Low audible chirp indicates alarm has been activated. Alarm
will sound when the exit device touchbar is depressed. Factory preset for standard alarm
mode which automatically resets after 5 minutes.
Continuous Alarm Mode: Alarm sounds
continuous when the exit device touchbar is depressed. Alarm must be manually reset by
keyswitch. (This feature is selected by a switch on the circuit board.)
Low Battery Warning: Audible chirp.
Warning Decal: "EMERGENCY EXIT-ALARM
WILL SOUND"
Nuisance Alarm: Factory preset for instant
alarm. Selectable feature for alarm to sound when exit device touchbar is depressed for
more than 2 seconds. (This feature is selected by a switch on the circuit board.)
Kit: Available in kit form for field
retrofit. Order 7116 Kit.
Arming Delay/ Authorized Egress: 10 Second
delay (after arming) permitting egress (by turning key clockwise).
Alarm Shunt: Ingress shunt alarm input for
devices with bolt status "S" monitor. NOTE: "S" included with SVR
devices.
Power Requirements: One 9 Volt Battery
(included).
Loudness: 90 db @ 10 feet.
Arm / Disarm: Uses one 1-1/8"
straight cam mortise cylinder. Clockwise turn arms the alarm, counter clockwise turn
disarms or silences the alarm.
Device Status: A red LED indicator
will illuminate every 30 seconds when the alarm is armed.
Tamper Resistant: Built in safety monitor
sounds alarm when tampering occurs. |