Homepage  
Search
find:
search for:
   
 
Site Navigation
News / Publications
Jobs
Service
   Add this page to Google Bookmarks
   Add this page to Mister Wong
   Add this page to del.icio.us
 
   Yale Security Inc.  Security Door Closers  

Security Door Closers - Page 10

 

 

 
Yale Security Inc.

4500 / 4500DPS SERIES

Standard Features

Concealed Transom Mounting: closer mounts is header of wood, aluminum or hollow metal frames; minimum 4''  (102mm) header required (A2'' x 4'' dust/grout box and a removable stop, provided by the door and frame supplier, is required.) Wood frame installation will generally require special offset templating.

Concealed Top Rail Mounted Slide Track: requires a minimum 2'' (51mm) top rail depth and a 1-3/4'' (44mm) minimum door thickness.

Concealed Arm: when door is closed: requires a 3/8'' deep door cutout for arm clearance.

Accommodates Most Door Hanging Methods: closer can be installed on doors hung on either butt hinges, offset or center pivots. Offset and center pivots supplied by others.

Shock Absorbing Door Stop: built into the slide track; non-hold-open closers have an adjustable block; hold-open closers have two springs that dead stop the door approximately 5° beyond the hold-open point. Use of an auxiliary door stop is always recommended.

Hold-Open Selector: in the slide track can be set to disengage when hold-open is not required; standard screwdriver operated through a 1/2'' (13mm) hole drilled in the door's top rail.

Adjustable Hold-Open Tension: increased or decreased by hex-key drive adjusting screw at the spring buffer end of the slide track.

Dress Plates: Supplied with the 4500DPS closer and are secured to bottom of closer with TORX screws. Prevents tampering and offers streamlined appearance.

Security Fasteners: (TORX) screws with security pin) furnished standard on 4500DPS, optional on 4500.

Hold -Open: in 5° increments by template location of slide track; range determined by how door is hung; order 4510/4510DPS Series.

Aluminum Alloy Shell: lightweight with proven durability.

Rack & Pinion Operation: assures smooth power transmission thru entire opening and closing cycles.

50% Spring Power Adjustment: power is adjustable up to 50% over minimum closing force for each closer size; spring adjustment gear assembly adjusted by a standard screw driver.

Adjustable Closing Speed: independent regulating valve; hex-key operated.

Adjustable Latch Speed: independent regulating valve; hex-key operated.

Adjustable Backcheck Cushioning: independent regulating valve; hex-key operated.

Adjustable Backcheck Positioning: independent regulating valve; hex-key operated.

Non-Critical Valves: all control valves are non-critical; operated by a 1/8'' hex-key.

Non-Hold-Open Arm:13'' (330mm) long with offset bend to permit 180° door opening; handed.

Hold-Open Arm: 16'' (406mm) long, straight; non-handed.

Separate Hinges/Pivots: hinges or pivots supplied by others therefore not packed with door closers; no early job site opening of closer package until closer is installed, no lost hardware.

Optional Features

450 Fire Block Door Liner: for use in 20 minute fire door assemblies where recognized fire door assemblies where recognized by local authorities having jurisdiction.

Adjustable Delayed Action Closing: delays closing at any point beyond 70° of door opening; for handicapped or wheeled traffic.

Accessibility Code Closer: available as 4500BFI Series for interior doors, 4500BFE Series for exterior doors, with low opening resistance to conform to the requirements of ANSI A117.1 Specifications. These closers provide reduced opening forces to conform with barrier code requirements for the handicapped and still provide acceptable door control,. Consult the Yale Marketing Department for application details of this closer.

Security Option 4500DPS

Door Position Switch (DPS): this switch is Single Pole Double Throw (SPDT) momentary contact, with one (1) normally open and one(1) normally closed set of contacts. The three switch terminals are wired to the integral conduit box for connection to incoming wiring. The switch and wiring are for operation with 6 to 24 VAV/VDC systems.

Door Position Switch Adjustment:Can be made at the opening without removing the closer from the frame. The door position adjustment test socket is accessible, during installation, for easy adjustment of the switch cam. Test probes from a volt meter are inserted into the test socket while using a 1/8'' hex wrench to adjust the ''Position Switch Adjustment''.

Test Socket: Volt meter or test light may be connected to test socket to test normally open circuit or normally closed circuit at the door opening. The door position switch may be adjusted at the same time without removal of closer from door.

*Request for Information / Request a Catalog
 
 
 
To request more information from Yale Security Inc., please complete the form below.
 
*Name:    
*Email:    
Company:    
*Company type:    
Phone:    
*Address:    
*Request:    
    (* = Mandatory field) 
Please add me to the mailing list for the free monthly e-Newsletter AECnews.  
     






Printable version Bookmark this page Notify a colleague or friend about this pageHome | Terms of Use | Privacy Statement | Link to AECinfo
AECinfo is a member of Docu Group, the world's largest building products information network.



Copyright © 1996–2008 AECinfo.com