PEMKO  

194. CSI 3-Part Specifications.

94A SPEC 194 Rev 1995

 

SPECIFIER NOTE:

THE FOLLOWING DATA IS INTENDED TO ASSIST IN SPECIFYING PEMKO

PRODUCTS. INCORPORATE IN A PROJECT SPECIFICATION WHERE

APPROPRIATE.

CAREFULLY REVIEW TO ENSURE COORDINATION WITH ALL CONTRACT

DOCUMENTS.

1. PRODUCT:Floor Plate Trim w/Support (3/4"x 1-3/8"), Pemko #194A

2. MANUFACTURER:

PEMKO * Ventura PEMKO * Memphis

4226 Transport Street 5535 Distribution Drive

Ventura, CA 93003 Memphis, TN 38141

Phone:(800) 283-9988 Phone (800) 824-3018

Fax: (800) 283-4050 Fax: (800) 243-3656

3. MATERIAL & FINISH:

SPECIFIER NOTE:

PRODUCT SELECTED IS AVAILABLE IN MATERIALS & FINISHES SPECIFIED

BELOW. WHERE MORE THAN ONE MATERIAL IS LISTED FOR A PRODUCT,

SELECT PARAGRAPH FOR MATERIAL YOU WANT.

EDIT BRACKETED TEXT TO SPECIFY FINISH. DELETE TEXT NOT DESIRED.

MATERIALS & FINISHES NOT LISTED MAY BE AVAILABLE BY SPECIAL

ORDER.

Aluminum, Extruded

* Alloy Type 6063-T5

* Chemical and physical properties per the Aluminum

Association, Inc.

* Federal Specification QQ-A-200/9C

* [194A Mill finish, 194D Dark bronze anodized,

194G Gold anodized].

Architectural bronze (brass), Extruded

* CDA alloy 38500 (56.5% Copper, 2.75% Lead, 40.7% Zinc,

0.05% alum.)

* [194B Mill finish, Oxidized & oil rubbed, Polished, Satin

brush]

4. TEST & CODE COMPLIANCE

Fire Label: Classified By UL For Application To Swinging

Type Fire Doors of the Hollow Metal or Steel

Covered composite type Rated up to 3 Hours, or

Wood Core Fire Doors rated up to 1-1/2 Hours.

Listed and Labeled as Gasketing Materials.

Tested in accordance with UL10B by Underwriters

Laboratory, Inc. .

5. INSTALLATION:

Installation to be performed in strict accordance with

manufacturer's instructions furnished with product.

Carefully cope to fit within the frame opening. Fasten with

flat head wood or machine screws provided and appropriate

anchors as required. Use a sealant or compound at all edges

and joints.

6. WARRANTY:

Guaranteed by manufacturer against defects in material or

workmanship for 3 years.