PEMKO  

FS1. CSI 3-Part Specifications.

CFS83 SPECIFICATION FS May 1995

SPECIFIER NOTE:

THE FOLLOWING DATA IS INTENDED TO ASSIST IN SPECIFYING PEMKO

PRODUCTS. INCORPORATE IN A PROJECT SPECIFICATION WHERE

APPROPRIATE.

CAREFULLY REVIEW TO ENSURE COORDINATION WITH ALL CONTRACT

DOCUMENTS.

1. PRODUCT: PemkoHinge Continuous Geared Hinge, Full Surface "FS"

Series, Standard Weight and Heavy Weight, CFS83 and

CFS83HD, 83" (7'-0") Height; CFS85 and CFS85HD, 85"

(7'-2") Height; CFS95 and CFS95HD, 95" (8'-0") Height;

CFS120 and CFS120HD, 120" (10'-0") Height.

 

2. MANUFACTURER:

PEMKO * Ventura PEMKO * Memphis

4226 Transport Street 5535 Distribution Drive

Ventura, CA 93003 Memphis, TN 38141

Phone: (800) 283-9988 Phone (800) 824-3018

Fax: (800) 283-4050 Fax: (800) 243-3656

3. MATERIAL & FINISH:

SPECIFIER NOTE:

PRODUCT SELECTED IS AVAILABLE IN MATERIALS & FINISHES SPECIFIED

BELOW.

EDIT BRACKETED TEXT TO SPECIFY FINISH. DELETE TEXT NOT DESIRED.

MATERIALS & FINISHES NOT LISTED MAY BE AVAILABLE BY SPECIAL

ORDER.

HINGE LEAVES AND CHANNEL CAP:

Aluminum, Extruded

* Alloy Type 6063-T5

* Chemical and physical properties per the Aluminum

Association, Inc.

* Federal Specification QQ-A-200/9C

* Template fastener locations.

* Template bearing locations

* Anodized after machining (drilling and milling)

* [CFS83, Clear anodized in accordance with 204-R1

(AA-M12C22A31) ;DFS83 Dark bronze anodized in accordance with

HC-II (AA-M12C22A44)]

BEARINGS:

Delrin II , Teflon filled

* (Delrin and Teflon are registered trademarks of Du Pont)

* Produced by patented process and composition.

* Number of bearings: 83" standard duty, 14; heavy duty, 27.

4. TEST & CODE COMPLIANCE:

Fire Label: Classified By Underwriters Laboratory Inc., United

States and Canada, For Use On Swinging Type Fire

Doors of the Hollow Metal, Tinclad, Sheetmetal and Steel

Covered Composite type Rated up to 3 Hours, or Wood

Covered Composite Type Rated Up To And Including

1-1/2 Hours. Also Wood Core Rated Up To And Including 20

Minutes Without Hose Stream.

Cycle Test: Certified by an independent, Underwriters

Laboratories Inc. approved testing laboratory for 1,500,000

cycles.

Meets requirements of ANSI/BHMA A156.1.

5. INSTALLATION:

Installation to be performed in strict accordance with

manufacturer's instructions furnished with product.

Properly mark, drill, and install factory supplied fasteners,

as specified in manufacturers charts and instructions

furnished with hinge.

6. WARRANTY:

Guaranteed by manufacturer against defects in material or

workmanship for THE LIFE OF THE OPENING.